pitz_gun_vac

Component name: |
pitz_gun_vac |
task: |
gun vacuum control |
CAF file: |
pitz_gun_vac.CAF |
DESY: |
PITZ DESY |
person / phone: |
Bert Schoeneich / 7373 |
called from: |
pitz |
host / server: |
ion pumps: |
pitzvme01.ifh.de / SVR.GP |
titan sublimation pumps: |
pitzvme01.ifh.de / SVR.TSP |
mobile pumpstations: |
pitzvme01.ifh.de / SVR.MOPUS |
valves: |
vmepitz03.ifh.de / SVR.DEV2ST |
|
Device Base Address: |
ion pumps: |
PITZ.VAC/ION_PUMP/*/ |
titan sublimation pumps: |
PITZ.VAC/TSP/*/ |
mobile pumpstations: |
PITZ.VAC/MOPUS/*/ |
valves: |
PITZ.VAC/DEV2ST/*/ |
|
comments: |
1 |
The sign for a mobile punpstation (8, 9, 10, 11 and 12) is a simple underline without "P" if no mobile pump
station is connected to this location. |
2 |
If the mobile pumpstation is not connected at one of the tunnel
points (8, 9, 10, 11 and 12), look in pitz_pumpstation_parking
(20). |
3 |
documentation of the old s5-pumpstation: pitz_pumpstation_win |
4 |
documentation of the new s7-pumpstation: pitz_pumpstation_s7 |
5 |
"curent pressure of all pumps": to see all pump
names extend the whole window in horizontal direction |
6 |
"curent pressure of all pumps": to see the
time-depending pressure of one pump, click on the pump name |
|
problems: |
|
contents: |
|
name / task / value |
click |
double click |
1 |
cathodes storage chamber |
|
|
2.1 |
valve (hand operated)
open |
|
close |
red: |
outlines and inner
circles |
|
|
pitz_valves |
|
2.2 |
valve (motor operated)
open |
|
close |
red: |
outlines and inner
circles |
|
|
pitz_valves |
|
3 |
ion pump |
ion_pump_win |
|
4 |
titan sublimation pump |
tsp_win |
|
5 |
cathode manipulator [linear (z-direction) and lateral (x-direction)
]
manipulator is in |
not out |
manipulator is out |
out |
|
|
|
7 |
cathodes loading chamber |
|
|
8 |
mobil pump station (tunnel, point TUNNEL1, see
comments 1, 2) |
pitz_pumpstation_s7 |
|
13 |
magnets - on the top of the magnets the current (readback
value) |
|
|
14 |
gun |
|
|
15 |
waveguide from the clystron |
|
|
18 |
diagnostic facilities |
pitz_diagnostic |
|
20 |
show the mobile pumpstation, if they are in a parking
position |
pitz_mobile_pumpstation_parking |
|
21 |
show all valves state |
pitz_valves |
|
23 |
current pressure of all pumps (see comments also) |
click on the pump name -> see the time-depending
pressure of this pump |
|
24 |
electron beam line |
|
|
30 |
help button |
this window |
|
|
|