PITZ - Photo Injector Test Facility - graphical user interface - documentation (DESY Zeuthen)
(table of contents v3.078)
Last modified: 23.02.2010 13:44:12

pitz_grabber_status
(revised for PITZ 1.6)

pitz_grabber_status

Component name: pitz_grabber_status
task: states of the camera frame grabber and the multiplexer
CAF file: pitz_grabber_status.CAF
DESY: DESY Zeuthen
person / phone: Bert Schoeneich / 7373
called from: pitz2_diagnostic
host / server: znppitzfg2 / SVC.VIDMUX
Device Base Address: PITZ.DIAG///
comments:

1

button vitalize frame grabber server behind each server name
(Stefan Weisse)

Simple explanation:

If 'valid video' indicator keeps yellow although you are sure that the camera you recently attached to the server is working fine, you may press vitalize and wait up to 20 seconds. After that, the server should start acquiring frames from that camera.

In-depth explanation:
During on-shift use of the Video System, all servers should remain stable, even if there are cameras switched off or on, are reconfigured or cables are disconnected and reconnected. However, one small glitch could not be automatically treated and requires help of the operator. It may happen that a camera slowly dies and renders the framegrabber card in a state where no video can be grabbed (although no error is reported by the software API), even if the server was switched to a fully working camera in the meantime.

The only choice is to stop the server via watchdog and let it start again by the watchdog service. After this procedure, the server should be again able to acquire video, if it was connected to a fully working camera before. The 'vitalize' button just does that, i.e. send a command to the watchdog to stop the server. After the server is stopped, it should be restarted automatically by the watchdog and starting to acquire frames again. Finally, the 'Server alive since ...' string should be updated soon.
problems:  
contents:
# name / task / value click double click
1 frame grabber name    
2 video and multiplexer server startup time    
3 camera currently connected to this frame grabber    
4 on multiplexer
yes
green:  
no
grey:  
   
6 camera started
yes
green:  
no
grey:  
   
7 valid video signal there
yes
green:  
no
yellow:  
   
8 camera stopped
yes
green:  
no
grey:  
   
9 framegrabber server startup time    
10 vitalize (restart) frame grabber server
(see comments)
do it  
30 help button this window  
   

Last modified: Februar 23, 2010 13:44 , Bert Schöneich, mailmailto: PITZ - webmaster