pitz_water_win

pitz_water_win

Component name: pitz_water-win
task: water control
CAF file: pitz_water_win.CAF
DESY: PITZ DESY
person / phone: Bert Schoeneich / 7373
called from: pitz
host / server: pitzvme01.ifh.de / SVR.PROF
Device Base Address: PITZ.VAC/PROF/WATER_C/
comments:  
problems:  
contents:
# name / task / value click -  window double click - window
1 gun    
2 temperature acknowledge readback history  
3 flow control (green: ok, red: not ok)    
4 temperature control (green: ok, red: not ok) history  
5 water to cooling circuit    
6 temperature of the outgoing water (no measurement!)    
7 suckpressure control (green: ok, red: not ok)    
8 show all status and other values of the pitz water control  pitz_water_expert  
9 pump (green: running, grey: not running)    
10 heater (green: running, grey: not running)    
11 heater temperature setpoint readback history  
12 3 way valve set or readback value upper limit  in percent
(100 % means cold line is more open)
   
13 3 way valve set or readback value in percent history  
14 3 way valve set or readback value upper limit  in percent
(0 % means hot line is more open)
   
15 water from cooling circuit    
16 temperature of the incoming water (no measurement!)    
17 3 way valve    
18 temperature setpoint readback history  
19 reset after error    
20 temperature setpoint lower limit    
21 temperature setpoint readback (the same like point 18) history  
22 temperature setpoint upper limit    
23 temperature setpoint input by writing a number change the value  
24.1 RF gun forward power
(If RPC.ERROR is not 0, an error occurs and 25 - 32 are not shown. In this place an error message and the error number will be displayed in red and yellow.)
show spectrum  
24.2 RF gun reflected power
(If RPC.ERROR is not 0, an error occurs and 25 - 32 are not shown. In this place an error message and the error number will be displayed in red and yellow.)
show spectrum  
25 forward power (V) history  
26 reflected power (V) history  
27 reflected slope history  
28 control limit for the automatic control of the water temperature by the water cooling system (range for possible temperature changing by automatic) history  
29 radio frequency (rf) pulse lenght history  
30 radio frequency (rf) pulse rate change the value  
31 forward slope history  
32 slope history  
33 water pressure hot (B) history  
34 water pressure cold (B) history  
35 gun temperature in detail (more sensors visible) pitz_gun_temperature  
36 water flow in liter per minute to the gun iris history  
37 water flow in liter per minute to the gun body history  
41 secure sign enable user logon  
42 logon user name    
43 disable user name disable user logon  
44 help button this window  
 