name / task / value |
click - window |
double click - window |
1 |
gun |
|
|
2 |
temperature acknowledge readback |
history |
|
3 |
flow control (green: ok, red: not ok) |
|
|
4 |
temperature control (green: ok, red: not ok) |
history |
|
5 |
water to cooling circuit |
|
|
6 |
temperature of the outgoing water (no measurement!) |
|
|
7 |
suckpressure control (green: ok, red: not ok) |
|
|
8 |
show all status and other values of the pitz water control |
pitz_water_expert |
|
9 |
pump (green: running, grey: not running) |
|
|
10 |
heater (green: running, grey: not running) |
|
|
11 |
heater temperature setpoint readback |
history |
|
12 |
3 way valve set or readback value upper limit in percent
(100 % means cold line is more open) |
|
|
13 |
3 way valve set or readback value in percent |
history |
|
14 |
3 way valve set or readback value upper limit in percent
(0 % means hot line is more open) |
|
|
15 |
water from cooling circuit |
|
|
16 |
temperature of the incoming water (no measurement!) |
|
|
17 |
3 way valve |
|
|
18 |
temperature setpoint readback |
history |
|
19 |
reset after error |
|
|
20 |
temperature setpoint lower limit |
|
|
21 |
temperature setpoint readback (the same like point 18) |
history |
|
22 |
temperature setpoint upper limit |
|
|
23 |
temperature setpoint input by writing a number |
change the value |
|
24.1 |
RF gun forward power
(If RPC.ERROR is not 0, an error occurs and 25 - 32 are not shown. In
this place an error message and the error number will be displayed
in red and yellow.) |
show spectrum |
|
24.2 |
RF gun reflected power
(If RPC.ERROR is not 0, an error occurs and 25 - 32 are not shown. In
this place an error message and the error number will be displayed
in red and yellow.) |
show spectrum |
|
25 |
forward power (V) |
history |
|
26 |
reflected power (V) |
history |
|
27 |
reflected slope |
history |
|
28 |
control limit for the automatic control of the water temperature
by the water cooling system (range for possible temperature changing
by automatic) |
history |
|
29 |
radio frequency (rf) pulse lenght |
history |
|
30 |
radio frequency (rf) pulse rate |
change the value |
|
31 |
forward slope |
history |
|
32 |
slope |
history |
|
33 |
water pressure hot (B) |
history |
|
34 |
water pressure cold (B) |
history |
|
35 |
gun temperature in detail (more sensors visible) |
pitz_gun_temperature |
|
36 |
water flow in liter per minute to the gun iris |
history |
|
37 |
water flow in liter per minute to the gun body |
history |
|
41 |
secure sign |
enable user logon |
|
42 |
logon user name |
|
|
43 |
disable user name |
disable user logon |
|
44 |
help button |
this window |
|